- LED Rate 2 Lighting Recover & Upgrade
- 45x Phillips RoadFlair L80 & L50 3000K Aeroscreen Luminaires
- Site Length - 1.2km
Features:
A combination of forty-five Phillips RoadFlair L80 and L50 3000K Aeroscreen luminaires, in a predominantly central double outreach configuration at a mounting height of 10.5m and maximum spacing of 52m. Install base plate steel poles in the centre median as traffic speed is 50km/h or less.
Single outreach street lights at intersections and bus stops at a mounting height of 10.5m. Columns are installed at 0.5m back of kerb to allow for separation from footpaths. Streetlights on the southern side of Noosa Parade 0.6m RP to avoid existing Energex cables installed underneath the road kerb. Streetlights in side streets at a mounting height of 9m and 0.7m back of kerb.
Overview:
Our Electrical Engineers determined the lighting category to be a combination of Category V5 of AS/NZS 1158.1.1 and PA3 AS/NZS 1158.3.1: 2020 at the raised traffic management devices and bus stops.
Key Constraints:
Our Electrical Engineers produced a compliant design that was heavily influenced by the existing Energex cables installed on a non-standard alignment, mature vegetation, pedestrian movement, public expectation and council budget constraints.
Associated Engineering Consultants:
Road upgrade designed by TOD Consulting Engineers
Accredited Energex Contractors:
Constructed by DSE Civil Electrical